Rental technical guide
Rental electrical planning — lighting, power & control
Rental electrical planning is a standardised lighting, power and control system: a guest can understand it without instructions, a cleaner can reset a room fast, and an operator can repeat the same specification across every unit. Positions and controls are planned by ELS; the wiring, protection and testing stay with a licensed electrician.
Light · Power · Control
One system a guest can read without instructions
Every rental electrical layout is planned across three sub-systems. Keep each one standardised and a cleaner can reset a room in seconds, a guest never hunts for a switch, and an operator repeats the same spec across every unit.
Light
- Ambient downlights
- Kitchen and desk task lighting
- Bedside reading lights
- Mirror lighting
- Cabinet and wardrobe lighting
- Selected feature lighting
Power
- 13A socket outlets
- USB-C charging
- Dedicated appliance points
- TV and router points
- Housekeeping sockets
- AC and water-heater isolators
Control
- Physical light switches
- Two-way bedside switching
- Master all-off switch
- Optional key-card control
- Occupancy sensors
- Smart AC and energy controls
- Circuit and switch labelling
The lighting standard
One colour temperature per sightline
A consistent lighting standard is the cheapest way a rental looks considered rather than accidental. Warm where people rest, cool where they work — and the two never mixed in the same view.
Lighting standard
| General ambient | 3000K |
|---|---|
| Bedroom and living | 3000K |
| Kitchen worktop | 4000K |
| Work desk工作桌Meja kerja | 3500–4000K |
| Bathroom mirror | 4000K |
| Wardrobe / display | 3000K |
| Colour rendering (CRI) | ≥90 |
| Cabinet lighting | 24V COB |
| Guest controls | Physical switch always provided |
| Smart controls | Optional secondary layer |
Avoid mixing 3000K, 4000K and 6500K inside one sightline.
Two planning levels
- Lighting plan
- Standard 3000K downlights
- 4000K kitchen task lights
- Standard white sockets and switches
- Bedside charging points
- Kitchen appliance points
- TV and router points
- Circuit schedule and labels
- Installation testing
- USB-C bedside sockets
- Master all-off
- Two-way bedside switching
- Wardrobe lighting
- Entrance night sensor
- Water-heater timer
- AC remote control
- Energy-monitoring readiness
Scene control, selected dimming, smart relays, occupancy sensing, track and feature lighting, automated curtains and premium faceplates.
Specified by ELS as part of a designed interior, not as a StayReady level — a scheme like this is drawn for one unit rather than repeated across a block.
The entrance master switch must not shut down:
- Refrigerator
- Router and mesh network
- Smart lock
- CCTV or security system
- Smoke and leak sensors
- Power-failure alert
- Essential exterior security lighting
- Any appliance that requires continuous power
1 Guest-controlled circuits2 Master-switch circuits3 Permanently-powered operational circuits
A failed smart hub must not prevent guests from switching on the lights.
Who does what
Positions are planned; wiring stays with a licensed electrician
Planning bands
How many points, by unit type
Standardised, per-unit-type quantities so every unit is specified the same way — and repeated. These are early estimator bands, not construction quantities.
| Unit type | Lighting points | Socket points | Switch groups |
|---|---|---|---|
| Studio / serviced room | 12–18 | 12–18 | 6–10 |
| 1-Bedroom | 18–26 | 16–24 | 9–14 |
| 2-Bedroom | 24–34 | 22–32 | 12–18 |
| 3-Bedroom / whole house | 32–46 | 28–40 | 16–24 |
| Co-living bedroom (per room) | 4–7 | 3–5 | 2–4 |
Co-living shared areas (kitchen, living, dining, entry) are added on top of the per-room band, using the shared-area room schedule below.
- Lighting point
- One fixture or one separately-controlled LED run.
- Socket point
- One faceplate — a double 13A outlet counts as one socket point.
- Switch group
- One faceplate, regardless of the number of gangs.
- Dedicated point
- Reserved for one appliance and labelled accordingly.
The room-by-room schedule
Every room, the same way, every time
The planning baseline behind the bands. Co-living shared and per-room rows are flagged. Final points, wet-zone positions and protection are confirmed by the licensed electrician.
| Room空间Ruang | Lighting照明Pencahayaan | Sockets & services | Switches & control |
|---|---|---|---|
| Entrance / foyer | 1–2 × 3000K downlights; optional motion night light | 1 × double 13A housekeeping socket; doorbell / intercom provision; smart-lock power if required | 1 × 2-gang switch; master all-off; optional key-card switch |
| Living room | 4–8 × 3000K downlights; optional 2–4 adjustable spotlights; floor / table-lamp provision | 2 × double 13A at TV wall; TV / data point; dedicated router point; 2 × sofa-side double sockets; 1 × housekeeping socket | 1 × 2–4-gang switch group; optional two-way switch; optional dimmer |
| Dining | 1 × pendant point; 2–4 × 3000K downlights | 1–2 × double 13A near dining / work area; optional USB-C | 1 × 1–2-gang switch; optional dimmer |
| Dry kitchen | 4–6 × 3000K ambient downlights; 4000K under-cabinet COB task light | 2–3 × double worktop sockets; dedicated refrigerator, microwave, hood and oven points; water-filter point; dishwasher point if applicable; cooker connection according to load; appliance points confirmed before cabinet production | 1 × 3–4-gang switch group; task-light switch; appliance isolators |
| Wet kitchen | 3–5 × ambient lights; 4000K worktop task light; hood / exhaust provision | 1–2 × double worktop sockets; dedicated hood, hob, refrigerator / freezer and washing points as required | 1 × 2–4-gang switch; separate hood / exhaust control; accessible isolators |
| Queen / king bedroom | 4–6 × 3000K downlights; 2 × bedside reading lights; optional wardrobe COB | 1 × bedside charging group each side; 1 × desk / dressing double socket; 1 × housekeeping socket; optional TV / data point; dedicated AC isolator | Entrance switch group; two-way master-light control at bedside; individual reading-light switches |
| Twin bedroom | 4–6 × 3000K downlights; 1 × reading light per bed; optional wardrobe COB | 1 × charging group per bed; 1 × desk socket; 1 × housekeeping socket; optional TV / data; AC isolator | Entrance switch; two-way control accessible from beds; individual reading-light switches |
| Single / co-living bedroomper room | 2–4 × 3000K downlights; 1 × bedside reading light; optional wardrobe light | 1 × bedside charging group; 1 × desk double socket; 1 × housekeeping socket; optional TV / data; AC isolator | Entrance switch; optional bedside two-way control; reading-light switch |
| Work / study / dressing | 2–4 × ambient lights; desk task light; optional mirror light | 2 × double 13A at desk; USB-C charging; optional data point; 1 × housekeeping socket | 1 × 1–2-gang switch; optional independent task-light control |
| Bathroom | 2 × suitable ambient downlights; 1 × 4000K mirror light; exhaust fan point | No general socket inside wet zones; water-heater connection; optional approved shaver point; hairdryer point outside wet area | Light and exhaust switches in approved dry position; water-heater double-pole isolator outside wet area |
| Laundry / utility | 2–4 × 4000K lights; optional cabinet / task COB | Dedicated washing-machine point; dedicated dryer point; 1 × double ironing / worktop socket; optional water-heater point | 1 × 2–3-gang switch; appliance isolators; optional exhaust control |
| Corridor | Downlight ≈ every 1.5–2.0 m subject to layout; optional night / motion light | 1 × housekeeping socket per corridor zone | Two-way control from both ends; optional motion sensor |
| Staircase | Ceiling / wall lighting; optional step or low-level night lighting | Optional housekeeping socket at landing | Two-way switches at top and bottom; optional night sensor |
| Balcony / exterior | 1–2 × suitable weather-resistant lights | Optional weatherproof socket in a compliant position | Internal switch or suitable weatherproof switch |
| Store / linen room | 1 × 3000K or 4000K ceiling light | Optional single / double socket | Door sensor or standard single switch |
| Co-living entry / common areashared | 2–4 × ambient lights; motion night light | Housekeeping socket; router / security point; door-access provision | Master control; permanently-powered operational circuits |
| Co-living shared dining / livingshared | 6–10 × ambient lights; dining pendant; optional feature lights | TV / data / router; sofa-side sockets; dining / work sockets; housekeeping socket | Zoned switching for living and dining; optional master control |
Detailed room standards
The depth behind the schedule
Expand a room for its Essential / Plus and lighting / sockets / control detail. Planning baselines only — the licensed electrician confirms final points and protection.
Entrance and foyer
Essential
- 1–2 ambient downlights
- One double housekeeping socket
- One two-gang switch
- Doorbell / intercom provision
- Smart-lock readiness
- Clear circuit and switch labels
Plus
- Motion-controlled night light
- Master all-off switch
- Smart-lock power-status alert
- Entrance scene controlling foyer and living lights
The master switch must not turn off the router, refrigerator, smart lock, security system or safety sensors.
Living room
Lighting
- 4–8 general 3000K downlights by size
- Optional adjustable spotlights for the TV / feature wall
- Optional concealed ambient lighting
- Provision for floor or table lamps
- No 6500K cool-white lighting
Sockets
- Two double sockets at the TV wall
- Dedicated television point
- Data / router point
- Streaming-device point
- One double socket near each sofa end
- One housekeeping / vacuum socket
- Optional balcony connection
Controls
- General ambient circuit
- Feature / spotlight circuit
- Concealed-lighting circuit
- Optional dimmer
- Two-way control where the room has more than one main access route
Keep the TV, router and streaming equipment on appropriately managed circuits; the router remains permanently powered.
Dining area
Lighting
- One centred pendant point where the table position is fixed
- Two to four supporting 3000K downlights
- Optional wall or feature light
Sockets
- One double socket near the dining area
- A second double socket if the table may be used for work
- Optional USB-C charging
- Avoid a floor socket unless the furniture position is permanently fixed
The dining pendant and downlights should be separately controlled.
Dry kitchen
Lighting
- 4–6 ambient 3000K downlights
- Continuous 4000K COB task lighting below overhead cabinets
- Optional cabinet / interior lighting
- Optional pendant above an island
Worktop sockets
- Two to three double 13A socket points
- Position sockets by kettle, rice-cooker and small-appliance zones
- Maintain suitable distance from sink and hob areas
Dedicated appliance points
- Refrigerator
- Microwave
- Hood
- Oven
- Dishwasher where provided
- Water filter / dispenser
- Induction hob or cooker connection to confirmed load
- Cabinet-lighting driver
- Optional island socket
All appliance models and electrical requirements must be confirmed before cabinet production.
Wet kitchen
Lighting
- Three to five ambient fixtures
- 4000K worktop task lighting
- Hood / exhaust provision
- Fixtures suited to moisture and heat exposure
Sockets
- One or two worktop double sockets
- Dedicated hood and hob points
- Refrigerator / freezer where applicable
- Washing-machine point if located here
- Water-filter or hot-water equipment point if required
Use accessible isolators and avoid placing sockets in direct washdown or splash areas.
Queen or king bedroom
Lighting
- Four to six 3000K downlights
- One reading light per bed side
- Optional wardrobe lighting
- Optional dressing / mirror lighting
Bedside charging group (per side)
- One double 13A switched socket
- One USB-C charging point
- Reading-light switch
- Two-way master-room-light switch in Plus
Additional points
- One double socket at desk / dressing table
- One housekeeping socket
- Optional TV / data point
- Dedicated AC isolator
Both sides of the bed must receive equal charging access.
Twin bedroom
One complete group per bed
- One double 13A socket per bed
- One USB-C point per bed
- One reading light per bed
- Independent reading-light switches
- Shared two-way room-light control
Do not place the only socket between the beds — the beds may later be separated.
Single or co-living bedroom
Essential
- Two to four 3000K ambient lights
- One bedside reading light
- One bedside double socket
- One desk double socket
- One housekeeping socket
- Dedicated AC isolator
Plus
- USB-C bedside charging
- Wardrobe sensor light
- Bedside two-way switch
- Optional data point
This is the standard repeated co-living bedroom electrical module.
Work and dressing area
Standard
- Two to four ambient lights depending on whether it is a separate room
- Dedicated desk task light
- Two double sockets at desk level
- USB-C charging
- Data point where wired connectivity is desired
- Hairdryer point where used as a dressing table
- Mirror light where applicable
- One accessible housekeeping socket
Desk points should not be hidden behind drawers or fixed cabinetry.
Bathroom
Lighting
- Two suitable ambient fixtures
- One 4000K mirror light
- Exhaust fan
- Optional low-level night light
Electrical
- Water-heater connection
- Double-pole water-heater isolator outside the wet area
- Exhaust-fan connection
- Optional approved shaver outlet
- Hairdryer point outside the wet area or at the bedroom dressing station
Do not install general-purpose socket outlets inside prohibited wet zones.
Laundry and utility
Lighting
- Two to four 4000K ceiling lights
- Worktop task light
- Cabinet light where storage is deep
Dedicated points
- Washing machine
- Dryer
- Ironing / worktop double socket
- Water heater if provided
- Exhaust fan
- Optional appliance-charging point
Washer and dryer points should remain accessible without removing the appliances.
Corridor and staircase
Corridor
- Downlight spacing based on ceiling height and beam angle
- Motion night lighting for Plus
- Housekeeping socket
- Two-way control from both ends
Staircase
- Main ceiling or wall lighting
- Optional low-level step lighting
- Two-way switch at top and bottom
- Emergency or power-failure provision where required by the project type
Balcony and exterior
Standard
- Weather-resistant wall or ceiling light
- Appropriate ingress protection
- Optional weatherproof socket
- Optional security camera / network point
- Optional motion sensor
- Internal isolation or switch control
Exterior points must not be improvised from indoor products.
The core products
A deliberately small electrical kit
Kept small on purpose so procurement stays repeatable across every unit.
Lighting照明Pencahayaan
SR-LT-DL303000K CRI≥90 ambient downlightSR-LT-DL404000K CRI≥90 task downlightSR-LT-SPOTAdjustable 3000K spotlightSR-LT-PENDCompact dining / island pendantSR-LT-COB3024V 3000K COB stripSR-LT-COB4024V 4000K COB stripSR-LT-BEDBedside reading lightSR-LT-MIR4000K mirror lightSR-LT-NIGHTMotion-controlled night lightSR-LT-EXTWeather-resistant exterior light
Sockets & services
SR-EL-SKT1Single switched 13A socketSR-EL-SKT2Double switched 13A socketSR-EL-USBCCertified USB-C charging socketSR-EL-DATAData / network pointSR-EL-TVTelevision pointSR-EL-ISO2020A double-pole isolatorSR-EL-COOK45Cooker connection / isolator where requiredSR-EL-WPWeatherproof exterior socket
Switches & controls
SR-EL-SW1One-gang switchSR-EL-SW2Two-gang switchSR-EL-SW3Three-gang switchSR-EL-SW4Four-gang switchSR-EL-SW2WTwo-way switchSR-EL-MASTERMaster all-off switchSR-EL-KEYKey-card switchSR-EL-DIMApproved dimmerSR-EL-MOTIONOccupancy / motion sensorSR-EL-METEREnergy-monitoring device
White is the standard finish across every StayReady unit. A second faceplate colour belongs to a designed interior, not to a repeatable baseline — and no third colour until volume justifies it.
Honest by default
Planning guidance — not an electrical contract
- Every quantity here is a planning baseline, not a final electrical drawing. Final points, circuit loads, wet-zone positions and protection must be confirmed by the licensed electrical contractor.
- Use Malaysian-standard switched 13A outlets — avoid universal international sockets, which can have weaker contact retention and inconsistent safety. Keep countertop sockets away from the sink, hob and splash zones; do not install general-purpose sockets inside wet zones. Final positioning follows the applicable wet-area and electrical requirements.
- This is planning guidance, not an electrical contract. Fixed wiring, circuit protection and testing stay under qualified electrical contractors and wiremen. Sockets, switches, dimmers, drivers and lamp fittings may require Energy Commission approval, so mains-voltage products use a certified Malaysian range.