Rental technical guide

Rental electrical planning — lighting, power & control

Rental electrical planning is a standardised lighting, power and control system: a guest can understand it without instructions, a cleaner can reset a room fast, and an operator can repeat the same specification across every unit. Positions and controls are planned by ELS; the wiring, protection and testing stay with a licensed electrician.

Every quantity here is a planning baseline, not a final electrical drawing. Final points, circuit loads, wet-zone positions and protection must be confirmed by the licensed electrical contractor.

Light · Power · Control

One system a guest can read without instructions

Every rental electrical layout is planned across three sub-systems. Keep each one standardised and a cleaner can reset a room in seconds, a guest never hunts for a switch, and an operator repeats the same spec across every unit.

Light

  • Ambient downlights
  • Kitchen and desk task lighting
  • Bedside reading lights
  • Mirror lighting
  • Cabinet and wardrobe lighting
  • Selected feature lighting

Power

  • 13A socket outlets
  • USB-C charging
  • Dedicated appliance points
  • TV and router points
  • Housekeeping sockets
  • AC and water-heater isolators

Control

  • Physical light switches
  • Two-way bedside switching
  • Master all-off switch
  • Optional key-card control
  • Occupancy sensors
  • Smart AC and energy controls
  • Circuit and switch labelling

The lighting standard

One colour temperature per sightline

A consistent lighting standard is the cheapest way a rental looks considered rather than accidental. Warm where people rest, cool where they work — and the two never mixed in the same view.

Lighting standard

General ambient3000K
Bedroom and living3000K
Kitchen worktop4000K
Work desk工作桌Meja kerja3500–4000K
Bathroom mirror4000K
Wardrobe / display3000K
Colour rendering (CRI)≥90
Cabinet lighting24V COB
Guest controlsPhysical switch always provided
Smart controlsOptional secondary layer

Avoid mixing 3000K, 4000K and 6500K inside one sightline.

Two planning levels

Essential
  • Lighting plan
  • Standard 3000K downlights
  • 4000K kitchen task lights
  • Standard white sockets and switches
  • Bedside charging points
  • Kitchen appliance points
  • TV and router points
  • Circuit schedule and labels
  • Installation testing
PlusEverything in Essential, plus:
  • USB-C bedside sockets
  • Master all-off
  • Two-way bedside switching
  • Wardrobe lighting
  • Entrance night sensor
  • Water-heater timer
  • AC remote control
  • Energy-monitoring readiness
Beyond the planning baseline

Scene control, selected dimming, smart relays, occupancy sensing, track and feature lighting, automated curtains and premium faceplates.

Specified by ELS as part of a designed interior, not as a StayReady level — a scheme like this is drawn for one unit rather than repeated across a block.

The critical master-switch rule

The entrance master switch must not shut down:

  • Refrigerator
  • Router and mesh network
  • Smart lock
  • CCTV or security system
  • Smoke and leak sensors
  • Power-failure alert
  • Essential exterior security lighting
  • Any appliance that requires continuous power

1 Guest-controlled circuits2 Master-switch circuits3 Permanently-powered operational circuits

A failed smart hub must not prevent guests from switching on the lights.

Who does what

Positions are planned; wiring stays with a licensed electrician

ELSLighting effect, point positions, switching logic and style approval.
StayReadyPackage selection, procurement, device coordination and QC.
ALUMAXCabinet-integrated lighting and related product installation.
Licensed electricianWiring, distribution board, protection, installation, testing and workmanship warranty.
Product supplierElectrical-product certification and product warranty.

Planning bands

How many points, by unit type

Standardised, per-unit-type quantities so every unit is specified the same way — and repeated. These are early estimator bands, not construction quantities.

Unit typeLighting pointsSocket pointsSwitch groups
Studio / serviced room12–1812–186–10
1-Bedroom18–2616–249–14
2-Bedroom24–3422–3212–18
3-Bedroom / whole house32–4628–4016–24
Co-living bedroom (per room)4–73–52–4

Co-living shared areas (kitchen, living, dining, entry) are added on top of the per-room band, using the shared-area room schedule below.

Lighting point
One fixture or one separately-controlled LED run.
Socket point
One faceplate — a double 13A outlet counts as one socket point.
Switch group
One faceplate, regardless of the number of gangs.
Dedicated point
Reserved for one appliance and labelled accordingly.

The room-by-room schedule

Every room, the same way, every time

The planning baseline behind the bands. Co-living shared and per-room rows are flagged. Final points, wet-zone positions and protection are confirmed by the licensed electrician.

Room空间RuangLighting照明PencahayaanSockets & servicesSwitches & control
Entrance / foyer1–2 × 3000K downlights; optional motion night light1 × double 13A housekeeping socket; doorbell / intercom provision; smart-lock power if required1 × 2-gang switch; master all-off; optional key-card switch
Living room4–8 × 3000K downlights; optional 2–4 adjustable spotlights; floor / table-lamp provision2 × double 13A at TV wall; TV / data point; dedicated router point; 2 × sofa-side double sockets; 1 × housekeeping socket1 × 2–4-gang switch group; optional two-way switch; optional dimmer
Dining1 × pendant point; 2–4 × 3000K downlights1–2 × double 13A near dining / work area; optional USB-C1 × 1–2-gang switch; optional dimmer
Dry kitchen4–6 × 3000K ambient downlights; 4000K under-cabinet COB task light2–3 × double worktop sockets; dedicated refrigerator, microwave, hood and oven points; water-filter point; dishwasher point if applicable; cooker connection according to load; appliance points confirmed before cabinet production1 × 3–4-gang switch group; task-light switch; appliance isolators
Wet kitchen3–5 × ambient lights; 4000K worktop task light; hood / exhaust provision1–2 × double worktop sockets; dedicated hood, hob, refrigerator / freezer and washing points as required1 × 2–4-gang switch; separate hood / exhaust control; accessible isolators
Queen / king bedroom4–6 × 3000K downlights; 2 × bedside reading lights; optional wardrobe COB1 × bedside charging group each side; 1 × desk / dressing double socket; 1 × housekeeping socket; optional TV / data point; dedicated AC isolatorEntrance switch group; two-way master-light control at bedside; individual reading-light switches
Twin bedroom4–6 × 3000K downlights; 1 × reading light per bed; optional wardrobe COB1 × charging group per bed; 1 × desk socket; 1 × housekeeping socket; optional TV / data; AC isolatorEntrance switch; two-way control accessible from beds; individual reading-light switches
Single / co-living bedroomper room2–4 × 3000K downlights; 1 × bedside reading light; optional wardrobe light1 × bedside charging group; 1 × desk double socket; 1 × housekeeping socket; optional TV / data; AC isolatorEntrance switch; optional bedside two-way control; reading-light switch
Work / study / dressing2–4 × ambient lights; desk task light; optional mirror light2 × double 13A at desk; USB-C charging; optional data point; 1 × housekeeping socket1 × 1–2-gang switch; optional independent task-light control
Bathroom2 × suitable ambient downlights; 1 × 4000K mirror light; exhaust fan pointNo general socket inside wet zones; water-heater connection; optional approved shaver point; hairdryer point outside wet areaLight and exhaust switches in approved dry position; water-heater double-pole isolator outside wet area
Laundry / utility2–4 × 4000K lights; optional cabinet / task COBDedicated washing-machine point; dedicated dryer point; 1 × double ironing / worktop socket; optional water-heater point1 × 2–3-gang switch; appliance isolators; optional exhaust control
CorridorDownlight ≈ every 1.5–2.0 m subject to layout; optional night / motion light1 × housekeeping socket per corridor zoneTwo-way control from both ends; optional motion sensor
StaircaseCeiling / wall lighting; optional step or low-level night lightingOptional housekeeping socket at landingTwo-way switches at top and bottom; optional night sensor
Balcony / exterior1–2 × suitable weather-resistant lightsOptional weatherproof socket in a compliant positionInternal switch or suitable weatherproof switch
Store / linen room1 × 3000K or 4000K ceiling lightOptional single / double socketDoor sensor or standard single switch
Co-living entry / common areashared2–4 × ambient lights; motion night lightHousekeeping socket; router / security point; door-access provisionMaster control; permanently-powered operational circuits
Co-living shared dining / livingshared6–10 × ambient lights; dining pendant; optional feature lightsTV / data / router; sofa-side sockets; dining / work sockets; housekeeping socketZoned switching for living and dining; optional master control

Detailed room standards

The depth behind the schedule

Expand a room for its Essential / Plus and lighting / sockets / control detail. Planning baselines only — the licensed electrician confirms final points and protection.

Entrance and foyer

Essential

  • 1–2 ambient downlights
  • One double housekeeping socket
  • One two-gang switch
  • Doorbell / intercom provision
  • Smart-lock readiness
  • Clear circuit and switch labels

Plus

  • Motion-controlled night light
  • Master all-off switch
  • Smart-lock power-status alert
  • Entrance scene controlling foyer and living lights

The master switch must not turn off the router, refrigerator, smart lock, security system or safety sensors.

Living room

Lighting

  • 4–8 general 3000K downlights by size
  • Optional adjustable spotlights for the TV / feature wall
  • Optional concealed ambient lighting
  • Provision for floor or table lamps
  • No 6500K cool-white lighting

Sockets

  • Two double sockets at the TV wall
  • Dedicated television point
  • Data / router point
  • Streaming-device point
  • One double socket near each sofa end
  • One housekeeping / vacuum socket
  • Optional balcony connection

Controls

  • General ambient circuit
  • Feature / spotlight circuit
  • Concealed-lighting circuit
  • Optional dimmer
  • Two-way control where the room has more than one main access route

Keep the TV, router and streaming equipment on appropriately managed circuits; the router remains permanently powered.

Dining area

Lighting

  • One centred pendant point where the table position is fixed
  • Two to four supporting 3000K downlights
  • Optional wall or feature light

Sockets

  • One double socket near the dining area
  • A second double socket if the table may be used for work
  • Optional USB-C charging
  • Avoid a floor socket unless the furniture position is permanently fixed

The dining pendant and downlights should be separately controlled.

Dry kitchen

Lighting

  • 4–6 ambient 3000K downlights
  • Continuous 4000K COB task lighting below overhead cabinets
  • Optional cabinet / interior lighting
  • Optional pendant above an island

Worktop sockets

  • Two to three double 13A socket points
  • Position sockets by kettle, rice-cooker and small-appliance zones
  • Maintain suitable distance from sink and hob areas

Dedicated appliance points

  • Refrigerator
  • Microwave
  • Hood
  • Oven
  • Dishwasher where provided
  • Water filter / dispenser
  • Induction hob or cooker connection to confirmed load
  • Cabinet-lighting driver
  • Optional island socket

All appliance models and electrical requirements must be confirmed before cabinet production.

Wet kitchen

Lighting

  • Three to five ambient fixtures
  • 4000K worktop task lighting
  • Hood / exhaust provision
  • Fixtures suited to moisture and heat exposure

Sockets

  • One or two worktop double sockets
  • Dedicated hood and hob points
  • Refrigerator / freezer where applicable
  • Washing-machine point if located here
  • Water-filter or hot-water equipment point if required

Use accessible isolators and avoid placing sockets in direct washdown or splash areas.

Queen or king bedroom

Lighting

  • Four to six 3000K downlights
  • One reading light per bed side
  • Optional wardrobe lighting
  • Optional dressing / mirror lighting

Bedside charging group (per side)

  • One double 13A switched socket
  • One USB-C charging point
  • Reading-light switch
  • Two-way master-room-light switch in Plus

Additional points

  • One double socket at desk / dressing table
  • One housekeeping socket
  • Optional TV / data point
  • Dedicated AC isolator

Both sides of the bed must receive equal charging access.

Twin bedroom

One complete group per bed

  • One double 13A socket per bed
  • One USB-C point per bed
  • One reading light per bed
  • Independent reading-light switches
  • Shared two-way room-light control

Do not place the only socket between the beds — the beds may later be separated.

Single or co-living bedroom

Essential

  • Two to four 3000K ambient lights
  • One bedside reading light
  • One bedside double socket
  • One desk double socket
  • One housekeeping socket
  • Dedicated AC isolator

Plus

  • USB-C bedside charging
  • Wardrobe sensor light
  • Bedside two-way switch
  • Optional data point

This is the standard repeated co-living bedroom electrical module.

Work and dressing area

Standard

  • Two to four ambient lights depending on whether it is a separate room
  • Dedicated desk task light
  • Two double sockets at desk level
  • USB-C charging
  • Data point where wired connectivity is desired
  • Hairdryer point where used as a dressing table
  • Mirror light where applicable
  • One accessible housekeeping socket

Desk points should not be hidden behind drawers or fixed cabinetry.

Bathroom

Lighting

  • Two suitable ambient fixtures
  • One 4000K mirror light
  • Exhaust fan
  • Optional low-level night light

Electrical

  • Water-heater connection
  • Double-pole water-heater isolator outside the wet area
  • Exhaust-fan connection
  • Optional approved shaver outlet
  • Hairdryer point outside the wet area or at the bedroom dressing station

Do not install general-purpose socket outlets inside prohibited wet zones.

Laundry and utility

Lighting

  • Two to four 4000K ceiling lights
  • Worktop task light
  • Cabinet light where storage is deep

Dedicated points

  • Washing machine
  • Dryer
  • Ironing / worktop double socket
  • Water heater if provided
  • Exhaust fan
  • Optional appliance-charging point

Washer and dryer points should remain accessible without removing the appliances.

Corridor and staircase

Corridor

  • Downlight spacing based on ceiling height and beam angle
  • Motion night lighting for Plus
  • Housekeeping socket
  • Two-way control from both ends

Staircase

  • Main ceiling or wall lighting
  • Optional low-level step lighting
  • Two-way switch at top and bottom
  • Emergency or power-failure provision where required by the project type
Balcony and exterior

Standard

  • Weather-resistant wall or ceiling light
  • Appropriate ingress protection
  • Optional weatherproof socket
  • Optional security camera / network point
  • Optional motion sensor
  • Internal isolation or switch control

Exterior points must not be improvised from indoor products.

The core products

A deliberately small electrical kit

Kept small on purpose so procurement stays repeatable across every unit.

Lighting照明Pencahayaan

  • SR-LT-DL30 3000K CRI≥90 ambient downlight
  • SR-LT-DL40 4000K CRI≥90 task downlight
  • SR-LT-SPOT Adjustable 3000K spotlight
  • SR-LT-PEND Compact dining / island pendant
  • SR-LT-COB30 24V 3000K COB strip
  • SR-LT-COB40 24V 4000K COB strip
  • SR-LT-BED Bedside reading light
  • SR-LT-MIR 4000K mirror light
  • SR-LT-NIGHT Motion-controlled night light
  • SR-LT-EXT Weather-resistant exterior light

Sockets & services

  • SR-EL-SKT1 Single switched 13A socket
  • SR-EL-SKT2 Double switched 13A socket
  • SR-EL-USBC Certified USB-C charging socket
  • SR-EL-DATA Data / network point
  • SR-EL-TV Television point
  • SR-EL-ISO20 20A double-pole isolator
  • SR-EL-COOK45 Cooker connection / isolator where required
  • SR-EL-WP Weatherproof exterior socket

Switches & controls

  • SR-EL-SW1 One-gang switch
  • SR-EL-SW2 Two-gang switch
  • SR-EL-SW3 Three-gang switch
  • SR-EL-SW4 Four-gang switch
  • SR-EL-SW2W Two-way switch
  • SR-EL-MASTER Master all-off switch
  • SR-EL-KEY Key-card switch
  • SR-EL-DIM Approved dimmer
  • SR-EL-MOTION Occupancy / motion sensor
  • SR-EL-METER Energy-monitoring device

White is the standard finish across every StayReady unit. A second faceplate colour belongs to a designed interior, not to a repeatable baseline — and no third colour until volume justifies it.

Honest by default

Planning guidance — not an electrical contract

  • Every quantity here is a planning baseline, not a final electrical drawing. Final points, circuit loads, wet-zone positions and protection must be confirmed by the licensed electrical contractor.
  • Use Malaysian-standard switched 13A outlets — avoid universal international sockets, which can have weaker contact retention and inconsistent safety. Keep countertop sockets away from the sink, hob and splash zones; do not install general-purpose sockets inside wet zones. Final positioning follows the applicable wet-area and electrical requirements.
  • This is planning guidance, not an electrical contract. Fixed wiring, circuit protection and testing stay under qualified electrical contractors and wiremen. Sockets, switches, dimmers, drivers and lamp fittings may require Energy Commission approval, so mains-voltage products use a certified Malaysian range.

Energy Commission controlled-equipment list · EC installation requirements